• Login
    View Item 
    •   Home
    • University Hospitals of Derby and Burton NHS Foundation Trust
    • Division of Surgery
    • Trauma and Orthopaedics
    • View Item
    •   Home
    • University Hospitals of Derby and Burton NHS Foundation Trust
    • Division of Surgery
    • Trauma and Orthopaedics
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Browse

    All of EMERCommunitiesPublication DateAuthorsTitlesSubjectsThis CollectionPublication DateAuthorsTitlesSubjectsProfilesView

    My Account

    LoginRegister

    Links

    About EMERPoliciesDerbyshire Community Health Services NHS Foundation TrustLeicester Partnership TrustNHS Nottingham and Nottinghamshire CCGNottinghamshire Healthcare NHS Foundation TrustNottingham University Hospitals NHS TrustSherwood Forest Hospitals NHS Foundation TrustUniversity Hospitals of Derby and Burton NHS Foundation TrustUniversity Hospitals Of Leicester NHS TrustOther Resources

    Statistics

    Most Popular ItemsStatistics by CountryMost Popular Authors

    Spontaneous Early Intraprosthetic Dislocation of 22 mm Skirted Femoral Head in Dual Mobility Hip Prosthesis: A Case Report.

    • CSV
    • RefMan
    • EndNote
    • BibTex
    • RefWorks
    Author
    Sidhu, Gur Aziz
    Kotecha, Amit
    Mulay, Sanjay
    Ashwood, Neil
    Keyword
    Intraprosthetic Dislocation
    Dual Mobility Cup
    Dislocation
    Total Hip Replacement
    
    Metadata
    Show full item record
    Abstract
    INTRODUCTION: There is a trend for increasing use of dual mobility hip designs for both primary and revision hip arthroplasty settings. It provides dual articular surfaces along with increased jump distance to increase the stability of construct. However, this design has some unique complications of its own which surgeons should be aware of especially intraprosthetic dislocation (IPD). CASE REPORT: A 76-year-old lady presented to clinic with painful hip hemiarthroplasty after fracture neck of femur. She underwent revision surgery with dual mobility uncemented acetabular cup and femoral stem was retained as it was well fixed. She was mobilizing well and around 5 weeks post her surgery, developed pain in hip region and difficulty in weight-bearing. Radiographs showed eccentric position of femoral neck in the socket. A diagnosis of IPD was established and revision surgery was planned. Intraoperatively, metal head had dislocated from the polyethylene head and both components were resting in the acetabular socket. No macroscopic erosion of acetabulum was noticed. The polyethylene component and femoral head were retrieved. With previous failed dual mobility, decision was made to achieve stability with larger head size and lipped liner posteriorly. CONCLUSION: IPD is a rare occurrence and unique complication to dual mobility implants. This report highlights that patients can have IPD without fall or trauma.
    Citation
    J Orthop Case Rep. 2021 Mar;11(3):6-9. doi: 10.13107/jocr.2021.v11.i03.2062.
    URI
    http://hdl.handle.net/20.500.12904/14805
    Collections
    Trauma and Orthopaedics

    entitlement

     
    DSpace software (copyright © 2002 - 2023)  DuraSpace
    Quick Guide | Contact Us
    Open Repository is a service operated by 
    Atmire NV
     

    Export search results

    The export option will allow you to export the current search results of the entered query to a file. Different formats are available for download. To export the items, click on the button corresponding with the preferred download format.

    By default, clicking on the export buttons will result in a download of the allowed maximum amount of items.

    To select a subset of the search results, click "Selective Export" button and make a selection of the items you want to export. The amount of items that can be exported at once is similarly restricted as the full export.

    After making a selection, click one of the export format buttons. The amount of items that will be exported is indicated in the bubble next to export format.