• Login
    View Item 
    •   Home
    • University Hospitals of Leicester NHS Trust
    • Musculoskeletal and Specialist Surgery
    • Orthopaedics
    • View Item
    •   Home
    • University Hospitals of Leicester NHS Trust
    • Musculoskeletal and Specialist Surgery
    • Orthopaedics
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Browse

    All of EMERCommunitiesPublication DateAuthorsTitlesSubjectsThis CollectionPublication DateAuthorsTitlesSubjectsProfilesView

    My Account

    LoginRegister

    Links

    About EMERPoliciesDerbyshire Community Health Services NHS Foundation TrustLeicester Partnership TrustNHS Nottingham and Nottinghamshire CCGNottinghamshire Healthcare NHS Foundation TrustNottingham University Hospitals NHS TrustSherwood Forest Hospitals NHS Foundation TrustUniversity Hospitals of Derby and Burton NHS Foundation TrustUniversity Hospitals Of Leicester NHS TrustOther Resources

    Statistics

    Most Popular ItemsStatistics by CountryMost Popular Authors

    Use of suture tapes versus conventional sutures for arthroscopic rotator cuff repairs: A systematic review and meta-analysis

    • CSV
    • RefMan
    • EndNote
    • BibTex
    • RefWorks
    Author
    Boksh, Khalis
    Haque, Aziz
    Sharma, Ashwini
    Divall, Pip
    Singh, Harvinder
    Keyword
    Systematic Review
    Rotator cuff
    Sutures
    Shoulder
    Date
    2021
    
    Metadata
    Show full item record
    DOI
    10.1177/0363546521998318
    Publisher's URL
    https://journals.sagepub.com/doi/10.1177/0363546521998318?url_ver=Z39.88-2003&rfr_id=ori:rid:crossref.org&rfr_dat=cr_pub%20%200pubmed
    Abstract
    Background: Various suture materials are available for arthroscopic rotator cuff repair. More recently, suture tapes have become popular as they are perceived to be easier to use with less soft tissue irritation. However, little is known about their biomechanical and clinical properties compared with conventional sutures in rotator cuff repairs. Purpose: To perform a systematic review and meta-analysis on whether suture tapes are biomechanically superior to conventional sutures in arthroscopic rotator cuff repairs and whether this translates to superior functional outcomes and a lower incidence of retears. Study design: Meta-analysis. Methods: The Cochrane Controlled Register of Trials, PubMed, Medline, and Embase were used to perform a systematic review and meta-analysis using the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) criteria with the following search terms: (rotator cuff repair OR arthroscopic rotator cuff repair) AND ("tape" OR "wire" OR "cord" OR "suture"). Data pertaining to certain biomechanical properties (contact area, contact pressure, gap formation, load to failure, and stiffness), retears, and patient-reported outcome measures (PROMs) were extracted. The pooled outcome data were analyzed by random- and fixed-effects models. Results: After abstract and full-text screening, 7 biomechanical and 6 clinical studies were included. All biomechanical studies were on animals, with 91 suture tapes and 91 conventional sutures compared. Suture tapes had higher contact pressure (mean difference [MD], 0.04 MPa; 95% CI, 0.01-0.08; P = .02), higher load to failure (MD, 52.62 N; 95% CI, 27.34-77.90; P < .0001), greater stiffness (MD, 4.47 N/mm; 95% CI, 0.57-8.38; P = .02), and smaller gap formation (MD, -0.30 mm; 95% CI, -0.45 to -0.15; P < .0001) compared with conventional sutures. From the clinical analysis of the 681 rotator cuff repairs treated with a suture tape (n = 380) or conventional suture (n = 301), there were no differences in retear rates between the groups (16% vs 20% suture tape and wire, respectively; P = .26) at a mean of 11.2 months. Qualitatively, there were no differences in PROMs between the groups at a mean of 36.8 months. Conclusion: Although biomechanically superior, suture tapes showed similar retear rates and postoperative function to conventional sutures. However, higher-quality clinical studies are required to investigate whether there are no true differences.
    Citation
    Boksh K, Haque A, Sharma A, Divall P, Singh H. Use of Suture Tapes Versus Conventional Sutures for Arthroscopic Rotator Cuff Repairs: A Systematic Review and Meta-analysis. American Journal of Sports Medicine. 2021 Mar 19:363546521998318.
    Type
    Article
    URI
    http://hdl.handle.net/20.500.12904/14867
    Collections
    Orthopaedics
    Libraries and Information Services

    entitlement

     
    DSpace software (copyright © 2002 - 2025)  DuraSpace
    Quick Guide | Contact Us
    Open Repository is a service operated by 
    Atmire NV
     

    Export search results

    The export option will allow you to export the current search results of the entered query to a file. Different formats are available for download. To export the items, click on the button corresponding with the preferred download format.

    By default, clicking on the export buttons will result in a download of the allowed maximum amount of items.

    To select a subset of the search results, click "Selective Export" button and make a selection of the items you want to export. The amount of items that can be exported at once is similarly restricted as the full export.

    After making a selection, click one of the export format buttons. The amount of items that will be exported is indicated in the bubble next to export format.