    About EMERPoliciesDerbyshire Community Health Services NHS Foundation TrustLeicester Partnership TrustNHS Nottingham and Nottinghamshire CCGNottinghamshire Healthcare NHS Foundation TrustNottingham University Hospitals NHS TrustSherwood Forest Hospitals NHS Foundation TrustUniversity Hospitals of Derby and Burton NHS Foundation TrustUniversity Hospitals Of Leicester NHS TrustOther Resources

    Statistics

    Most Popular ItemsStatistics by CountryMost Popular Authors

    Accidental neutron exposure in a medical setting: a case study

    • CSV
    • RefMan
    • EndNote
    • BibTex
    • RefWorks
    Author
    Peet, Debbie
    Keyword
    Monte Carlo modelling
    biological dosimetry
    gamma
    medical physics
    neutron
    Date
    2020
    
    Metadata
    Show full item record
    Publisher's URL
    https://iopscience.iop.org/article/10.1088/1361-6498/abc738
    Abstract
    In May 2016, a new linear accelerator (Linac) was installed at a hospital oncology department. A team of individuals supervised the installation, including a Radiation Oncologist who acted as an independent observer to the installation, calibration, beam data collection and shielding measurements. In order to ensure the shielding was correct, a licensed representative of the Turkish Atomic Energy Authority carried out formal measurements of the gamma and neutron dose rates at a variety of locations in and around the Linac facility. At 18 MV, the maximum neutron dose rate was 172μSv h-1and the maximum gamma dose rate was approximately 2μSv h-1(ambient dose equivalent in both cases), significantly higher than the expected and local background doses. As the neutron dose rates in particular were so high, it was concluded that the shielding was not sufficient, potentially due to an inadequate design. In order to rule out overexposure during the installation, biological dosimetry was carried out for a number of the individuals involved. The estimated doses were closely aligned with the doses measured using commercially available neutron dosemeters and were also within the tolerance dose ranges estimated using Monte Carlo simulations, which also supported the investigation. The results underline the need for careful planning before and after installation of new radiation exposure facilities, especially high MV Linac operation for which photo-neutrons might need to be mitigated. The results clearly indicate the importance of such checks, in addition to demonstrating the relevance of biological dosimetry supported by modelling strategies complex or unclear exposure scenarios.
    Citation
    Ainsbury, E. A., Eakins, J., Güçlü, İ., Kırbaşoğlu, Ç., Peet, D., & Tosun, I. (2020). Accidental neutron exposure in a medical setting: a case study. Journal of radiological protection : official journal of the Society for Radiological Protection, 40(4), 10.1088/1361-6498/abc738. https://doi.org/10.1088/1361-6498/abc738
    Type
    Article
    URI
    http://hdl.handle.net/20.500.12904/15143
    Collections
    Imaging

    entitlement

     
    DSpace software (copyright © 2002 - 2023)  DuraSpace
    Quick Guide | Contact Us
    Open Repository is a service operated by 
    Atmire NV
     

    Export search results

    The export option will allow you to export the current search results of the entered query to a file. Different formats are available for download. To export the items, click on the button corresponding with the preferred download format.

    By default, clicking on the export buttons will result in a download of the allowed maximum amount of items.

    To select a subset of the search results, click "Selective Export" button and make a selection of the items you want to export. The amount of items that can be exported at once is similarly restricted as the full export.

    After making a selection, click one of the export format buttons. The amount of items that will be exported is indicated in the bubble next to export format.