dc.identifier.citationGuy, S., Kitchen, S., Hopkins, B., Chunara, Z., Stephenson-Brown, A., & van Veen, J. J. (2022). Laboratory methods for monitoring argatroban in heparin-induced thrombocytopenia. International journal of laboratory hematology, 44(2), 399–406. https://doi.org/10.1111/ijlh.13757en_US
dc.identifier.urihttp://hdl.handle.net/20.500.12904/15766
dc.description.abstractIntroduction: The Summary of Product Characteristics for the direct thrombin inhibitor argatroban states monitoring should be by activated partial thromboplastin time (APTT), with a target range of 1.5-3.0 times the patients' baseline APTT. APTT may be influenced by coagulopathies, lupus anticoagulant and raised FVIII levels. Previous studies have shown sensitivity differences of APTT reagents to argatroban. Some recent publications have favoured the use of anti-IIa methods to determine the plasma drug concentration of argatroban. This study aims to compare the anti-IIa assays: Hemoclot thrombin inhibitor assay (HTI) and Ecarin chromogenic assay (ECA) alongside the APTT. Methods: Residual plasma of 25 samples from 8 patients (3 with COVID-19 and HIT: n = 18, 5 with HIT: n = 7) was tested at two sites: site A: Sysmex CS5100 by HTI and APTT (Actin FS and SynthASil), and also on Stago STA Compact Max: ECA and APTT (CK Prest); and site B: Stago STA R Max 2 by ECA and APTT (Cephascreen). Results: Mean APTT ratio was 1.96 (Actin FS), 1.84 (SynthASil), 1.59 (CK Prest) and 2.48 (Cephascreen). Mean argatroban concentration by HTI was 0.60 µg/mL and by ECA was 0.65 µg/mL (site A) and 0.70 µg/mL (site B). There was a poor correlation to HTI in APTT ratios (range r2 = .0235-0.4181) with stronger correlations between ECA methods to HTI (r2 = .8998 site A, r2 = .8734 site B). Conclusion: This study confirms previous publications on the unsuitability of APTT and expands this by being multisited and included APTT reagents that use mechanical clot detection. Both anti-IIa methods are more suitable.
dc.description.urihttps://onlinelibrary.wiley.com/doi/10.1111/ijlh.13757en_US
dc.language.isoenen_US
dc.subjectAPTTen_US
dc.subjectecarin chromogenic assayen_US
dc.subjectHITen_US
dc.subjectargatrobanen_US
dc.subjectdilute thrombin timeen_US
dc.titleLaboratory methods for monitoring argatroban in heparin-induced thrombocytopeniaen_US
dc.typeArticleen_US
rioxxterms.funderDefault funderen_US
rioxxterms.identifier.projectDefault projecten_US
rioxxterms.versionNAen_US
rioxxterms.versionofrecord10.1111/ijlh.13757en_US
rioxxterms.typeJournal Article/Reviewen_US
refterms.panelUnspecifieden_US
html.description.abstractIntroduction: The Summary of Product Characteristics for the direct thrombin inhibitor argatroban states monitoring should be by activated partial thromboplastin time (APTT), with a target range of 1.5-3.0 times the patients' baseline APTT. APTT may be influenced by coagulopathies, lupus anticoagulant and raised FVIII levels. Previous studies have shown sensitivity differences of APTT reagents to argatroban. Some recent publications have favoured the use of anti-IIa methods to determine the plasma drug concentration of argatroban. This study aims to compare the anti-IIa assays: Hemoclot thrombin inhibitor assay (HTI) and Ecarin chromogenic assay (ECA) alongside the APTT. Methods: Residual plasma of 25 samples from 8 patients (3 with COVID-19 and HIT: n = 18, 5 with HIT: n = 7) was tested at two sites: site A: Sysmex CS5100 by HTI and APTT (Actin FS and SynthASil), and also on Stago STA Compact Max: ECA and APTT (CK Prest); and site B: Stago STA R Max 2 by ECA and APTT (Cephascreen). Results: Mean APTT ratio was 1.96 (Actin FS), 1.84 (SynthASil), 1.59 (CK Prest) and 2.48 (Cephascreen). Mean argatroban concentration by HTI was 0.60 µg/mL and by ECA was 0.65 µg/mL (site A) and 0.70 µg/mL (site B). There was a poor correlation to HTI in APTT ratios (range r2 = .0235-0.4181) with stronger correlations between ECA methods to HTI (r2 = .8998 site A, r2 = .8734 site B). Conclusion: This study confirms previous publications on the unsuitability of APTT and expands this by being multisited and included APTT reagents that use mechanical clot detection. Both anti-IIa methods are more suitable.en_US
rioxxterms.funder.project94a427429a5bcfef7dd04c33360d80cden_US


This item appears in the following Collection(s)

Show simple item record