• Login
    View Item 
    •   Home
    • Nottingham University Hospitals NHS Trust
    • Clinical Support
    • Medical Physics and Clinical Engineering
    • View Item
    •   Home
    • Nottingham University Hospitals NHS Trust
    • Clinical Support
    • Medical Physics and Clinical Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Browse

    All of EMERCommunitiesPublication DateAuthorsTitlesSubjectsThis CollectionPublication DateAuthorsTitlesSubjectsProfilesView

    My Account

    LoginRegister

    Links

    About EMERPoliciesDerbyshire Community Health Services NHS Foundation TrustLeicester Partnership TrustNHS Nottingham and Nottinghamshire CCGNottinghamshire Healthcare NHS Foundation TrustNottingham University Hospitals NHS TrustSherwood Forest Hospitals NHS Foundation TrustUniversity Hospitals of Derby and Burton NHS Foundation TrustUniversity Hospitals Of Leicester NHS TrustOther Resources

    Statistics

    Most Popular ItemsStatistics by CountryMost Popular Authors

    Increased fasting small-bowel water content in untreated coeliac disease and scleroderma as assessed by magnetic resonance imaging

    • CSV
    • RefMan
    • EndNote
    • BibTex
    • RefWorks
    Thumbnail
    Name:
    Increased fasting small‐bowel ...
    Size:
    1.428Mb
    Format:
    PDF
    Download
    Author
    Lam, Ching
    Lanyon, Peter
    Marciani, Luca
    Hoad, Caroline L
    Costigan, Carolyn
    Spiller, Robin C
    Keyword
    Celiac disease
    Gastrointestinal contents
    Magnetic resonance imaging
    Date
    2019
    
    Metadata
    Show full item record
    Publisher's URL
    https://dx.doi.org/10.1177/2050640619860372
    Abstract
    Background and aims: The regular overnight migrating motor complex (MMC) ensures that the normal fasting small-bowel water content (SBWC) is minimised. We have applied our recently validated non-invasive magnetic resonance technique to assess SBWC in newly diagnosed coeliac disease (CD), scleroderma (SCD) and irritable bowel syndrome (IBS), conditions possibly associated with small intestinal bacterial overgrowth (SIBO)., Methods: A total of 20 CD and 15 SCD patients with gastrointestinal symptoms were compared to 20 healthy volunteers (HV) and 26 IBS with diarrhoea (IBS-D) patients, as previously reported. All underwent a fasting magnetic resonance imaging (MRI) scan on a 1.5 T Philips Achieva MRI scanner to assess fasting SBWC and colonic volumes. Stool and symptom diaries were completed for one week., Results: Compared to HV, all patients had significantly increased stool frequency and Bristol stool form score. SBWC was significantly increased in CD (median 109 mL; interquartile range (IQR) 53-224 mL) compared to HV (median 53 mL; IQR 31-98 mL; p < 0.01) and IBS-D (median 42 mL; IQR 28-67 mL; p < 0.01). A variable increase in SBWC was also found in SCD (median 77 mL; IQR 39-158 mL), but this was not significant (p = 0.2). Colonic volumes were similar for all groups, being a median of 547 mL (IQR 442-786 mL) for CD, 511 mL (453-789 mL) for SCD, 612 mL (445-746 mL) for HV and 521 mL (428-757 mL) for IBS-D. When CD patients were subdivided according to the Marsh classification, the higher grades had larger colonic volumes., Conclusion: Fasting SBWC as assessed by MRI is significantly increased in newly diagnosed CD and SCD but decreased in IBS-D. Future studies should test whether increased resting fluid predisposes to SIBO. Copyright © Author(s) 2019.
    Citation
    Lam, C., Sanders, D.S., Lanyon, P., Garsed, K., Foley, S., Pritchard, S., Marciani, L., Hoad, C.L., Costigan, C., Gowland, P. and Spiller, R. (2019) 'Increased fasting small-bowel water content in untreated coeliac disease and scleroderma as assessed by magnetic resonance imaging', United European gastroenterology journal, 7(10), pp. 1353-1360. doi: https://dx.doi.org/10.1177/2050640619860372.
    Publisher
    John Wiley and Sons Ltd
    Type
    Article
    URI
    http://hdl.handle.net/20.500.12904/15854
    Collections
    Medical Physics and Clinical Engineering
    Healthcare Scientists

    entitlement

     
    DSpace software (copyright © 2002 - 2025)  DuraSpace
    Quick Guide | Contact Us
    Open Repository is a service operated by 
    Atmire NV
     

    Export search results

    The export option will allow you to export the current search results of the entered query to a file. Different formats are available for download. To export the items, click on the button corresponding with the preferred download format.

    By default, clicking on the export buttons will result in a download of the allowed maximum amount of items.

    To select a subset of the search results, click "Selective Export" button and make a selection of the items you want to export. The amount of items that can be exported at once is similarly restricted as the full export.

    After making a selection, click one of the export format buttons. The amount of items that will be exported is indicated in the bubble next to export format.