Show simple item record

dc.contributor.authorBhandari, Sanjay
dc.contributor.authorKovac, Jan
dc.date.accessioned2023-03-21T14:36:13Z
dc.date.available2023-03-21T14:36:13Z
dc.date.issued2021-11-18
dc.identifier.citationGunarathne, A., Tan, J., Varcoe, R., Bhandari, S., Faour, A., Tanseco, K., Mylotte, D., Mitchell, A., Armario, X., Owens, C., Spence, M., Cunnington, M., Casserly, I., Kovac, J., Hildick-Smith, D., & Baig, K. (2022). The impact of learning-curve-experience on transcatheter aortic valve replacement outcomes: Insights from the United Kingdom and Ireland all-comers second-generation ACURATE neo™ transcatheter aortic heart valve registry. Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions, 99(4), 1172–1180. https://doi.org/10.1002/ccd.30000en_US
dc.identifier.other10.1002/ccd.30000
dc.identifier.urihttp://hdl.handle.net/20.500.12904/16540
dc.description.abstractBackground: The ACURATE neo™ is a novel, second-generation self-expanding supra-annular transcatheter heart valve (THV). The objective of this multi-centre registry is to assess the safety, clinical utility, and impact of 'learning-curve-experience' (LCE) on transcatheter aortic valve replacement outcomes in the United Kingdom (UK) and Ireland. Methods: We prospectively collected data from seven ACURATE neo™ THV implanting centres (n = 484) between February 2016 and November 2020. We compared mortality rates and outcomes in the LCE group (n = 120) compared to next successive 120 cases. Results: The mean age of the cohort was 81.9(SD: 6.1) years and the majority were in the moderate risk category (EuroSCORE-II):3.3(SD: 3). The 97.5% of cases were performed under local anesthetic. The valve was successfully deployed in 98.8% of cases. The survival rate at 30 days was 97.9%. The incidence of stroke was 2.5%. Life threatening bleeding occurred in 0.6% of cases and vascular access complications occurred in 21 (4.3%) patients. Implantation-related conduction abnormalities occurred in 8.3% but only 5.6% required a PPM. The successful valve deployment occurred in 96% of the patients in the LCE group compared to 100% in the other group (p = 0.04; OR-2[CI 1.7-2.3]). The mortality rates at 30 days (1.7% vs. 1.7%) and 1 year (1.9% vs. 2.7%) were comparable between the two groups. Conclusions: This study represents the largest published UK and Ireland real-world experience of the ACURATE neo™ valve. The procedural success rates and safety outcomes were excellent and endorse its utility in clinical practice. The LCE appears to have an impact on the successful valve deployment but without translating into short-term or long-term outcomes.
dc.description.urihttps://onlinelibrary.wiley.com/doi/10.1002/ccd.30000en_US
dc.language.isoenen_US
dc.subjectAortic diseaseen_US
dc.subjectAortic valve disease percutaneous interventionen_US
dc.subjectTranscatheter valve implantationen_US
dc.titleThe impact of learning-curve-experience on transcatheter aortic valve replacement outcomes: Insights from the United Kingdom and Ireland all-comers second-generation ACURATE neo™ transcatheter aortic heart valve registryen_US
dc.typeArticleen_US
rioxxterms.funderDefault funderen_US
rioxxterms.identifier.projectDefault projecten_US
rioxxterms.versionNAen_US
rioxxterms.versionofrecordhttps://doi.org/10.1002/ccd.30000en_US
rioxxterms.typeJournal Article/Reviewen_US
refterms.panelUnspecifieden_US
html.description.abstractBackground: The ACURATE neo™ is a novel, second-generation self-expanding supra-annular transcatheter heart valve (THV). The objective of this multi-centre registry is to assess the safety, clinical utility, and impact of 'learning-curve-experience' (LCE) on transcatheter aortic valve replacement outcomes in the United Kingdom (UK) and Ireland. Methods: We prospectively collected data from seven ACURATE neo™ THV implanting centres (n = 484) between February 2016 and November 2020. We compared mortality rates and outcomes in the LCE group (n = 120) compared to next successive 120 cases. Results: The mean age of the cohort was 81.9(SD: 6.1) years and the majority were in the moderate risk category (EuroSCORE-II):3.3(SD: 3). The 97.5% of cases were performed under local anesthetic. The valve was successfully deployed in 98.8% of cases. The survival rate at 30 days was 97.9%. The incidence of stroke was 2.5%. Life threatening bleeding occurred in 0.6% of cases and vascular access complications occurred in 21 (4.3%) patients. Implantation-related conduction abnormalities occurred in 8.3% but only 5.6% required a PPM. The successful valve deployment occurred in 96% of the patients in the LCE group compared to 100% in the other group (p = 0.04; OR-2[CI 1.7-2.3]). The mortality rates at 30 days (1.7% vs. 1.7%) and 1 year (1.9% vs. 2.7%) were comparable between the two groups. Conclusions: This study represents the largest published UK and Ireland real-world experience of the ACURATE neo™ valve. The procedural success rates and safety outcomes were excellent and endorse its utility in clinical practice. The LCE appears to have an impact on the successful valve deployment but without translating into short-term or long-term outcomes.en_US
rioxxterms.funder.project94a427429a5bcfef7dd04c33360d80cden_US


This item appears in the following Collection(s)

Show simple item record