Show simple item record

dc.contributor.authorChoudhary, Pratik
dc.date.accessioned2024-04-02T13:20:43Z
dc.date.available2024-04-02T13:20:43Z
dc.date.issued2024-03
dc.identifier.citationLiarakos, A. L., Hasan, N., Crabtree, T. S. J., Leelarathna, L., Hammond, P., Hussain, S., Haq, M., Aslam, A., Gatdula, E., Gibb, F. W., Lumb, A., Bull, K., Chinnasamy, E., Carrieri, G., Williams, D. M., Choudhary, P., Ryder, R. E. J., & Wilmot, E. G. (2024). Real-world outcomes of Omnipod DASH system use in people with type 1 diabetes: Evidence from the Association of British Clinical Diabetologists (ABCD) study. Diabetes research and clinical practice, 209, 111597. https://doi.org/10.1016/j.diabres.2024.111597en_US
dc.identifier.other10.1016/j.diabres.2024.111597
dc.identifier.urihttp://hdl.handle.net/20.500.12904/18441
dc.description.abstractAims: To evaluate real-world outcomes in people with Type 1 Diabetes (PwT1D) initiated on Omnipod DASH® Insulin Management System. Methods: Anonymized clinical data were submitted to a secure web-based tool within the National Health Service network. Hemoglobin A1c (HbA1c), sensor-derived glucometrics, total daily dose of insulin (TDD), and patient-reported outcome changes between baseline and follow-up were assessed. Individuals were classified to "new-to-pump" (switched from multiple daily injections) and "established-on-pump" (switched from a tethered insulin pump) groups. Results: 276 individuals from 11 centers [66.7 % female; 92 % White British; median age 41 years (IQR 20-50); diabetes duration 20 years (IQR 11-31); 49.3 % within "new-to-pump" group] were included. Baseline HbA1c was 8.0 ± 1.3 % (64 ± 14 mmol/mol). At follow-up [3 years (IQR 1.5-3.2)], HbA1c reduced by 0.3 % [(3 mmol/mol); p = 0.002] across the total population, 0.4 % [(5 mmol/mol); p = 0.001] in those "new-to-pump" and remained unchanged in those "established-on-pump". TDD decreased in the "new-to-pump" cohort (baseline:44.9 ± 21.0units vs follow-up:38.1 ± 15.4units, p = 0.002). Of those asked, 141/143 (98.6 %) stated Omnipod DASH had a positive impact on quality of life. Conclusions: Omnipod DASH was associated with improvements in HbA1c in PwT1D "new-to-pump" and maintained previous HbA1c levels in those "established-on-pump". User satisfaction in all groups and TDD reduction in those "new-to-pump" were reported.
dc.description.urihttps://www.diabetesresearchclinicalpractice.com/article/S0168-8227(24)00081-0/fulltexten_US
dc.language.isoenen_US
dc.subjectContinuous subcutaneous insulin infusionen_US
dc.subjectDiabetes technologyen_US
dc.subjectOmnipod DASHen_US
dc.subjectTubeless insulin pumpen_US
dc.subjectType 1 diabetes mellitusen_US
dc.titleReal-world outcomes of Omnipod DASH system use in people with type 1 diabetes: Evidence from the Association of British Clinical Diabetologists (ABCD) studyen_US
dc.typeArticleen_US
rioxxterms.funderDefault funderen_US
rioxxterms.identifier.projectDefault projecten_US
rioxxterms.versionNAen_US
rioxxterms.versionofrecordhttps://doi.org/10.1016/j.diabres.2024.111597en_US
rioxxterms.typeJournal Article/Reviewen_US
refterms.panelUnspecifieden_US
html.description.abstractAims: To evaluate real-world outcomes in people with Type 1 Diabetes (PwT1D) initiated on Omnipod DASH® Insulin Management System. Methods: Anonymized clinical data were submitted to a secure web-based tool within the National Health Service network. Hemoglobin A1c (HbA1c), sensor-derived glucometrics, total daily dose of insulin (TDD), and patient-reported outcome changes between baseline and follow-up were assessed. Individuals were classified to "new-to-pump" (switched from multiple daily injections) and "established-on-pump" (switched from a tethered insulin pump) groups. Results: 276 individuals from 11 centers [66.7 % female; 92 % White British; median age 41 years (IQR 20-50); diabetes duration 20 years (IQR 11-31); 49.3 % within "new-to-pump" group] were included. Baseline HbA1c was 8.0 ± 1.3 % (64 ± 14 mmol/mol). At follow-up [3 years (IQR 1.5-3.2)], HbA1c reduced by 0.3 % [(3 mmol/mol); p = 0.002] across the total population, 0.4 % [(5 mmol/mol); p = 0.001] in those "new-to-pump" and remained unchanged in those "established-on-pump". TDD decreased in the "new-to-pump" cohort (baseline:44.9 ± 21.0units vs follow-up:38.1 ± 15.4units, p = 0.002). Of those asked, 141/143 (98.6 %) stated Omnipod DASH had a positive impact on quality of life. Conclusions: Omnipod DASH was associated with improvements in HbA1c in PwT1D "new-to-pump" and maintained previous HbA1c levels in those "established-on-pump". User satisfaction in all groups and TDD reduction in those "new-to-pump" were reported.en_US
rioxxterms.funder.project94a427429a5bcfef7dd04c33360d80cden_US


This item appears in the following Collection(s)

Show simple item record