• Login
    View Item 
    •   Home
    • Northamptonshire Healthcare NHS Foundation Trust
    • Ambulatory, Therapy, Diabetes Services
    • Podiatry
    • View Item
    •   Home
    • Northamptonshire Healthcare NHS Foundation Trust
    • Ambulatory, Therapy, Diabetes Services
    • Podiatry
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Browse

    All of EMERCommunitiesPublication DateAuthorsTitlesSubjectsThis CollectionPublication DateAuthorsTitlesSubjectsProfilesView

    My Account

    LoginRegister

    Links

    About EMERPoliciesDerbyshire Community Health Services NHS Foundation TrustLeicester Partnership TrustNHS Nottingham and Nottinghamshire CCGNottinghamshire Healthcare NHS Foundation TrustNottingham University Hospitals NHS TrustSherwood Forest Hospitals NHS Foundation TrustUniversity Hospitals of Derby and Burton NHS Foundation TrustUniversity Hospitals Of Leicester NHS TrustOther Resources

    Statistics

    Most Popular ItemsStatistics by CountryMost Popular Authors

    Biomechanical comparison of medio-plantar and plantar plate fixation for first tarsometatarsal joint arthrodesis

    • CSV
    • RefMan
    • EndNote
    • BibTex
    • RefWorks
    Thumbnail
    Name:
    Uddin 2023 3896.pdf
    Size:
    1.158Mb
    Format:
    PDF
    Download
    Author
    Uddin, Akram
    Keyword
    Hallux Valgus
    Bunion
    Biomechanical Phenomena
    Date
    2023
    
    Metadata
    Show full item record
    DOI
    https://doi.org/10.3390/jcm12123896
    Publisher's URL
    https://www.mdpi.com/2077-0383/12/12/3896
    Abstract
    Plantar plate positioning has been demonstrated as biomechanically superior. However, some operators remain resentful about the morbidity of the surgical approach. To provide improved plate fixation for first tarsometatarsal joint arthrodesis with respect to the tibialis anterior tendon, a medio-plantar plate was developed. The purpose of this biomechanical study was to compare its construct stability to that of a plantar plate construct. Twelve pairs of fresh frozen human specimens were used in a matched pair test. Each pair was fixed with a 4 mm compression screw and either a plantar locking plate or a medio-plantar locking plate. A cantilever beam test was performed in dorsiflexion. Before and after cyclic loading (5000 cycles; 40 N), bending stiffness and relative movements at the joint space were monitored in a quasi-static test including optical motion tracking. Maximum load and bending moment to failure were investigated in a load-to-failure ramp test. The bending stiffness of both groups did not significantly differ before (plantar 49.9 N/mm ± 19.2; medio-plantar 53.9 N/mm ± 25.4, p = 0.43) or after (plantar 24.4 N/mm ± 9.7; medio-plantar 35.3 N/mm ± 22.0, p = 0.08) cyclic loading but decreased significantly in both groups (p < 0.01) after cyclic loading. Relative movement increased significantly during cyclic testing in both groups (p < 0.01) but did not differ significantly between the groups before (p = 0.29) or after (p = 0.16) cyclic loading. Neither load nor bending moment to failure were significantly different (plantar 225 N ± 78, 10.8 Nm; medio-plantar 210 N ± 86, 10.1 Nm, p = 0.61). Both plate constructs provided equivalent construct stability, both being well suited for Lapidus arthrodesis.
    Citation
    Klos, K., Simons, P., Schopp, P., Schenk, P., Kohler, F. C., Uddin, A., Roth, E. K., Biedermann, U., Hofmann, G. O., & Lenz, M. (2023). Biomechanical comparison of medio-plantar and plantar plate fixation for first tarsometatarsal joint arthrodesis. Journal of Clinical Medicine, v12(12) article: 3896. https://doi.org/10.3390/jcm12123896
    Type
    Article
    URI
    http://hdl.handle.net/20.500.12904/18913
    Note
    Copyright: © 2023 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https:// creativecommons.org/licenses/by/4.0/).
    Collections
    Podiatry

    entitlement

     
    DSpace software (copyright © 2002 - 2025)  DuraSpace
    Quick Guide | Contact Us
    Open Repository is a service operated by 
    Atmire NV
     

    Export search results

    The export option will allow you to export the current search results of the entered query to a file. Different formats are available for download. To export the items, click on the button corresponding with the preferred download format.

    By default, clicking on the export buttons will result in a download of the allowed maximum amount of items.

    To select a subset of the search results, click "Selective Export" button and make a selection of the items you want to export. The amount of items that can be exported at once is similarly restricted as the full export.

    After making a selection, click one of the export format buttons. The amount of items that will be exported is indicated in the bubble next to export format.