Show simple item record

dc.contributor.authorPhillips, Margaret
dc.date.accessioned2017-09-12T16:03:23Z
dc.date.available2017-09-12T16:03:23Z
dc.date.issued2017-09
dc.identifier.citationBMJ Open. 2017 Sep 5;7(9):e015927. doi: 10.1136/bmjopen-2017-015927.language
dc.identifier.urihttp://hdl.handle.net/20.500.12904/364
dc.description.abstractOBJECTIVES: To assess the effectiveness of orthotic devices for the management of instability of the knee in adults with a neuromuscular disorder or central nervous system disorder. DESIGN: A systematic review of primary studies. SETTING: Community. PARTICIPANTS: Adults with a neuromuscular disorder or central nervous system disorder and impaired walking ability due to instability of the knee. INTERVENTIONS: Orthoses with the clinical aim of controlling knee instability, for example, knee-ankle-foot orthoses, ankle-foot orthoses and knee orthoses or mixed design with no restrictions in design or material. PRIMARY AND SECONDARY OUTCOME MEASURES: Condition-specific or generic patient-reported outcome measures assessing function, disability, independence, activities of daily living, quality of life or psychosocial outcomes; pain; walking ability; functional assessments; biomechanical analysis; adverse effects; usage; patient satisfaction and the acceptability of a device; and resource utilisation data. RESULTS: Twenty one studies including 478 patients were included. Orthotic devices were evaluated in patients with postpolio syndrome, poststroke syndrome, inclusion body myositis and spinal cord injury. The review included 2 randomised controlled trials (RCTs), 3 non-randomised controlled studies and 16 case series. Most were small, single-centre studies with only 6 of 21 following patients for 1 year or longer. They met between one and five of nine quality criteria and reported methods and results poorly. They mainly assessed outcomes related to gait analysis and energy consumption with limited use of standardised, validated, patient-reported outcome measures. There was an absence of evidence on outcomes of direct importance to patients such as reduction in pain and falls. CONCLUSIONS: There is a need for high-quality research, particularly RCTs, of orthotic devices for knee instability related to neuromuscular and central nervous system conditions. This research should address outcomes important to patients. There may also be value in developing a national registry. REGISTRATION NUMBER SYSTEMATIC REVIEW: PROSPERO (CRD42014010180).language
dc.language.isoenlanguage
dc.subjectCentral Nervous System Disorderlanguage
dc.subjectKnee Instabilitylanguage
dc.subjectNeuromuscular Diseaselanguage
dc.subjectOrthotic Deviceslanguage
dc.subjectSystematic Reviewlanguage
dc.titleSystematic review of the evidence on orthotic devices for the management of knee instability related to neuromuscular and central nervous system disorders.language
dc.typeArticlelanguage
refterms.dateFOA2021-06-03T09:46:34Z


Files in this item

Thumbnail
Name:
(431) BMJ Open.pdf
Size:
565.9Kb
Format:
PDF

This item appears in the following Collection(s)

Show simple item record